The causes to the output problem are listed in the timeframe that you've owned your RO system. The grey background applies to systems in use for under 3 months and the white background applies to systems in use for more than 3 months.
When trying to identify the causes of slow and little output. Isolate the RO system by shutting off your dependant applicances. Such as: ice-maker, fridge and humidifier.
The causes are listed from the most frequent and probable to the least likeliest.
| Causes | Identify | Solution | ||
| 1 | Feed water blocked | Make sure all lines to the RO system and within the RO head are not obstructed | Untangles the lines | |
| 2 | Input pressure too low | If your home pressure is within the model's regulation. Make sure you have the right model. | Make sure all the feed valves are fully turned on or exchange for the appropriate model | |
| 3 | Wrong Line Installation | 
Using RO pictures and the owner's manual. Make sure all lines are correctly connected. | RO-Pump | |
| 4 | Excessive Demand | Make sure the model's capacity can support your humidifier, ice-maker and fridge's demand | 
 | |
| 5 | Defective Pump (Extremely Rare) | 
 Pump is not operating at full capacity: 20psi input should translate to about 62psi 30psi input should translate to about 67psi 40psi input should transate to about 70psi Add a pressure gauge after P2 and stage 2 filter. See if the pressure increase is apparent | ||
| 6 | 
 Defective Membrane Housing (Extremely Rare) | Waste water flows non stop down the drain line and no RO water. | Replace the membrane housing. Contact Us | |
| 7 | Clogged Pre-filters | 
 See the condition of the first stage filter. To make it easier, you can consider upgrading to a see thru first stage housing. | ||
| 8 | Clogged Membrane | |||
| 9 | Tank pressure too low | 
 An empty 4 gallon tank should have 5 psi and an empty 14 gallon tank should have 7 psi 
 | ||
| 10 | Tank bladder ruptured | 
 Tank fills full but water leaks from the tank's pressure valve. Furthermore, a raptured tank tends to be heavier than a normal full tank. | ||
| 11 | 
 Check valve clogged (Very Rare) | Replace the Check Valve | ||